Sales & Support: Request A Quote
Home ProductsFlammability Testing Equipment

IEC61241 Minimum Ignition Temperature Tester for Electrical Products

IEC61241 Minimum Ignition Temperature Tester for Electrical Products

    • IEC61241 Minimum Ignition Temperature Tester for Electrical Products
    • IEC61241 Minimum Ignition Temperature Tester for Electrical Products
    • IEC61241 Minimum Ignition Temperature Tester for Electrical Products
  • IEC61241 Minimum Ignition Temperature Tester for Electrical Products

    Product Details:

    Place of Origin: CHINA
    Brand Name: AI
    Certification: ISO
    Model Number: AIC-61241

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 SET
    Price: Negotiable
    Packaging Details: Plywood case
    Delivery Time: 40 days
    Payment Terms: Western Union, T/T, L/C
    Supply Ability: 20 sets per month
    Contact Now
    Detailed Product Description
    Test Standard: IEC61241,EN 50281-2-1 Test Temperature Range: Room Temperature ~ 800 ºC
    Power Supply: 230v / 50Hz Or 110v / 60Hz. Size: 500X300X450 Mm
    Keyword: The Minimum Ignition Temperature Tester Warranty: 1 Year
    Display: LCD

    The Minimum Ignition Temperature Tester

     

    Introduction
    The Minimum Ignition Temperature Tester is a way of testing the sensitivity of the ignition that the dust cloud is in the heated environment. When a lot of dust is exposed in heating the air and the air temperature is high enough, it may lead to spontaneous combustion. This method can test the minimum ignition temperature of combustible dust cloud.

     

     

    Standard:

    • IEC 61241-2-1:1994:Electrical apparatus for use in the presence of combustible dust - Part 2: Test methods - Section 1: Methods for determining the minimum ignition temperatures ofdust
    • EN 50281-2-1:1999:Electrical apparatus for use in the presence of combustible dust - Part 2-1: Test methods - Methods for determining the minimum ignition temperatures of dust

     

    Technical parameters:

    1 Furnace operating temperature range

    Room temperature ~ 800 ºC.

    The operating temperature can rise to 1000 ºC to clean the test chamber

    2 emperature accuracy ± 1% (higher than 500 ºC), ± 3% (lower than 300 ºC).
    3 The pressure of the dispersion air chamber 0 ~ 1 bar
    4 The pressure accuracy of the air storage device ± 5%
    5 Size 500X300X450 mm
    6 Power supply 230v / 50Hz or 110v / 60Hz

     

     

    Testing process
    The Test is carried on the in Godbert-Greenwald furnace. The heating furnace is consist of the vertical quartz tubes . The hole is at the bottom of the tube.The glass observing room is connected with sample fixing device at the top of the quartz tubes. The compressed air from the tank blows the dust into the heating furnace and the sample fixing device ,and then exposed into the glass observing room and the quartz tubes .the heating furnace is located on the holder . And you can observe the ignition appearance from the bottom of the furnace. The test begins from the 500ºC. If you observe the ignition appearance ,you shall decrease the temperature at the 10ºC,until the ignition does not appear.

     

     

    Results description
    When the ignition occurs , the lowest temperature is recorded as the minimum ignition temperature of the dust cloud .
    The minimum ignition temperature of the test data information is used to determine whether the surface temperature of the equipment can cause the automatic fire of the exposed dust . It is an important standard to evaluate the selection of the equipment at the condition of the dusty environment . When using the minimum ignition temperature testing data ,you shall leave a safety limit for the small-scale test .