Sales & Support: Request A Quote
Home ProductsElectrical Test Instrument

15KV Digital Voltage Adjustable Megohmmeter Megohmmeter Insulation Resistance Meter

15KV Digital Voltage Adjustable Megohmmeter Megohmmeter Insulation Resistance Meter

    • 15KV Digital Voltage Adjustable Megohmmeter Megohmmeter Insulation Resistance Meter
    • 15KV Digital Voltage Adjustable Megohmmeter Megohmmeter Insulation Resistance Meter
    • 15KV Digital Voltage Adjustable Megohmmeter Megohmmeter Insulation Resistance Meter
    • 15KV Digital Voltage Adjustable Megohmmeter Megohmmeter Insulation Resistance Meter
  • 15KV Digital Voltage Adjustable Megohmmeter Megohmmeter Insulation Resistance Meter

    Product Details:

    Place of Origin: CHINA
    Brand Name: AI
    Certification: ISO
    Model Number: ADM-15KV

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 PC
    Price: Negotiable
    Packaging Details: Carton
    Delivery Time: 15 days
    Payment Terms: Western Union, T/T, L/C
    Supply Ability: 100000 sets per month
    Contact Now
    Detailed Product Description
    Measuring Range: 1,2.5,5,10,15kV Display: Digital
    Keyword: Megohmmeter, Megger, Insulation Resistance Meter Weight: 5.5KG
    Warranty: 1 Year Voltage Accuracy: ±(5%+10V)

    15KV Digital Voltage Adjustable Megohmmeter Megohmmeter Insulation Resistance Meter

     

    I.Introduction

    For safety, before using the instrument must be well earthed,because the measured target connecting to high voltage power exists power frequency leakage.
    Once high voltage being started, do not use manual discharge method to check the instrument. After test, please wait the instrument complete automatic discharge and automatically return to zero, then manual discharge can be operated. That is because electrical pulse caused by short-circuit discharge will damage the insulation life of the measured object; if the pulse fleeing into the instrument,it will also damage the integrated circuit inside the instrument.
    The instrument is designed for HV substations and power plants to test the characteristic of large HV transformer, electric machines and appliances, remote power cable or buried cable and other electrical insulation resistance in strong interference environment.

    It also can be widely used for testing characteristics of insulation resistance in other area.

     

     

    II. Main feature

     

    1. With strong anti-electric field interference ability up to 2mA (50Hz), it is suitable for 500kV substation without dismantling wire to test insulation resistance of 500kV large-scale transformer.
    2. The short-circuit current of test power> 5mA, maximum up to 15mA. Be suitable for testing high capacity and high inductance.
    3. Wide resistance range from 0.5MΩ ~ 1999GΩ. With high-resolution, having accurate readings.
    4. Wide voltage range: 0.25kV, 0.5kV, 1kV, 2.5kV, 5kV, 10kV, 15 kV/20kV, you can smoothly adjust voltage from 0V to the desired value.
    5. With timekeeping function, remind users to record, and analyze absorptance and polarization index of measured target.

     

    III.Technical Specifications

    Mode Test voltage Voltage accuracy Short-circuit current
    ADM-5kV 0.25,0.5,1,2.5,5kV ±(5%+10V) 10mA
    ADM-10kV 0.5,1,2.5,5,10kV ±(5%+10V) 10mA
    ADM-15kV 1,2.5,5,10,15kV ±(5%+10V) 10mA
    ADM-20kV 0.5,1,2.5,5,10,20kV ±(5%+10V) 10mA

     

    Range and accuracy

     

    Range Resistance measurement range Accuracy
    20MΩ/500V 0.5~19.99 MΩ ±(5%+5digital)
    200MΩ/1000V 5.0~199.9 MΩ ±(5%+5digital)
    2GΩ 0.05~1.999 GΩ ±(5%+5digital)
    20GΩ 0.5~19.99 GΩ ±(5%+5digital)
    200GΩ 5.0~199.9 GΩ ±(10%+10digital)
    2000GΩ 50~1999 GΩ Less than 1000GΩ ± (20% + 10 digital) (humidity ≤70%)

    Calibration voltage of MΩ range is 0.5kV; Calibration voltage of GΩ range is 2.5kV

    Anti-electric field interference ability 2mA(50Hz)  
    Timekeeping and alarm function maximum value of stopwatch is 19 minutes and 59 seconds. 20 minutes for a cycle. The stopwatch will tell the time at these time points: 15 seconds, 60 seconds and every 60 seconds. When telling time, resistance readings hold for 5 seconds. If the measured resistance is below the lower limit of range, the reading is invalid and the instrument will continuously sound to give an alarm
    Display three and a half bits LCD digital meter (three), respectively show test voltage, test resistance, test time
    Power supply

    10×1.2Vbattery(2000mAh Ni-MH rechargeable battery), total DC12V power supply

    AC: 220V (50/60Hz)

    Operating Conditions Temperature:0~40℃ Relative humidity:20~90%
    Dimension 315×240×155mm3
    Weight 5.5kg

     

    Photo of 15KV Digital Voltage Adustable Megohmmeter Megger Insulation Resistance Meter