Sales & Support: Request A Quote
Home ProductsFlammability Testing Equipment

16 CFR 1633 Mattress Flammability Testing Equipment Large Furnace Calorimeter

16 CFR 1633 Mattress Flammability Testing Equipment Large Furnace Calorimeter

    • 16 CFR 1633 Mattress Flammability Testing Equipment Large Furnace Calorimeter
    • 16 CFR 1633 Mattress Flammability Testing Equipment Large Furnace Calorimeter
    • 16 CFR 1633 Mattress Flammability Testing Equipment Large Furnace Calorimeter
  • 16 CFR 1633 Mattress Flammability Testing Equipment Large Furnace Calorimeter

    Product Details:

    Place of Origin: CHINA
    Brand Name: AI
    Certification: ISO
    Model Number: AIC-9705

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 SET
    Price: Negotiable
    Packaging Details: Plywood case
    Delivery Time: 60 days
    Payment Terms: Western Union, T/T, L/C
    Contact Now
    Detailed Product Description
    Test Standard: 16 CFR 1633,ISO 9705-2 Weight: 7,500kg
    Dimension: 11,725(W)x4,000(D)x4,750(H)mm Console Size: 600(W)×750(D)×1800(H)mm
    Color: White Keyward: Mattress Flammability Testing Equipment

    16 CFR 1633 Mattress Flammability Testing Equipment

    INTRODUCTION:

    This apparatus is designed according to GB/T 34441-2017, it can test combustion performance of soft furniture mattress exposed to flame ignition source.
    The test part of this equipment can meet the requirements of GB/T 20286, GA 111-1995, ISO 9705-2, GB/T 27904-2011 and GB/T 25207-2010 "Test Method for Solid Room Fire of Surface Products"

     

    Standards:

    GB/T 34441-2017
    GB/T 20286-2006
    GA 111-1995
    ISO 9705-2
    GB/T 27904-2011
    16 CRF 1633.

     

    FEATURE:

    Main features
    1.Testing room: Testing room can be built as closed or open(CFR 1633 standard requires test room can be built as closed or open.)
    Closed test room:
     The room is made of rock wool board. There are no openings except door and video surveillance windows
     The size of the test room is 3660 ± 25mm in length, 3050 ± 25mm in width and 2438 ±25mm in height.
     The door is 2032 ± 6 mm high and 965 ± 6 mm wide.
     Quartz glass monitor window, size 150x150mm.
     The fume hood is located outside the door (smoke outlet) to collect smoke;
    Open test room:
     The fume hood is positioned directly above the sample and the bottom edge is 2400 mm away from the ground.
     Conical collector size: 3000mm X 3000mm, height 1000mm
     The conical collector has 900mm X 900mm X 900mm X 900mm cubic mixing chamber on the top, and the mixer is installed inside
    2.The smoke exhaust pipe consists of a diversion section (x2), a straight section, a measuring section and a fan
     The measuring section is equipped with wind speed probe, thermocouple, optical
    system and sampler.
     Smoke exhaust capacity of fan is not less than 0.5m³/s
    3.Control cabinet
     19 inch standard cabinet, simple appearance, science and technology
     Control system center, integrated computer, display, analyzer, cold trap, control and
    data acquisition system.
     19 inch display, Labview control software, electronic control and pneumatic
    configuration panel.
     Computer: CPU I3, memory 4G, hard disk 500G Win7/Win10 system
    4.Equipped with imported analyzer (domestic analyzer is optional)
     Measurement of Gas Concentration of O2, CO2 and CO.
     O2:The range is 0-100%, the error is less than 0.01%, the repeatability is less than
    0.01%, and the response time is less than 7s.
     CO2: Range: 0-10%, error: 1% FS, repeatability < 2%, response time < 7s
     CO: range 0-1%, error 1% FS, repeatability < 1%, response time < 8s
    5.Optical system, one-button 5-level automatic transmittance calibration device.Light source is 0.5mW Laser Generator.
     Imported Silicon-based Amplified Photoelectric Detector
     Imported filters (25%, 50%, 79%)
     Motor Driven Optical Wheel and Positioning Device
    6.Wind Speed Control System Two-way probe, 304 stainless steel, 32mm in length and 14mm in diameter, separated into two separate chambers
     Imported Micro-differential Pressure Transmitter, Range 0-2000 Pa, Resolution 1%FS
     Three-phase frequency converter fan, closed-loop control of frequency converter, wind speed can be set, adjustable
    7.Gas sampling system
     Sampler, 304 Stainless Steel
     Ash filter, secondary filter, precision filter (0.2um), three-stage filter system, remove impurity particles in sample gas.
     Refrigerator, compressor condenser, precise control of the temperature of gas collected at 4℃±1℃, condensation dewatering
     Deep filtration of moisture in sample gas by discolored silica gel
     Aspirator pump:gas sampling system adopts sampling diaphragm pump displacement of 10L/min~50L/min
    8.Gas control system
     Burner:consisting of two T-shaped burners, surface burner and side burner
    Surface burner
     Stainless steel pipe, diameter 12.7 mm, wall thickness 0.89 + 0.5 mm.
     Burner length 306mm, sealed at both ends.
     There are 17 holes in the length of 136 mm on both sides of the central axis. The distance between holes is 8.5 mm, the diameter of holes is 1.45-1.53 mm, and the hole and the horizontal plane are 5°.
    Side burner
     Stainless steel pipe, diameter 12.7 mm, wall thickness 0.89 ± 0.5 mm
     Burner length 255mm, sealed at both ends
     There are 14 holes in 110 mm length on both sides of the central axis, with a distance of 8.5 mm and an aperture of 1.45-1.53mm.
     Mass Flow Controller
     Mass Flow Controller, control the Gas Flow Accurately.
     Surface burner, flow rate 12.9L/min. Side burner, flow rate 6.6L/min.
     Surface and side burner heat release rate total 27KW
     Ignition Controller
     15KV High Voltage Pulse Electron Fire
     Flame detection function, ignition failure or flame extinction, the controller will automatically cut off the gas valve.
    9.Weighing system (optional, standard GB 20286, GBT27904)
     The weighing system adopts C3 imported weighing sensor, and the weighing data is collected linearly and stored automatically.
     Waterproof design of weighing system to prevent damage to heavy system during fire fighting
    10.Video recording
     12 Megapixel HD Camera
     Video Recording Software
    11. Software
     The interface of LABVIEW is modern, simple and rich in functions.
     The software adopts modular design, independent modules such as system setup, system calibration, test, test report, etc.
     The test data can be read by engineering units and physical units, and displayed by data windows and curves and charts.
     The data you want to view can be selected by checking.
     Provide preview function of test report, which can be printed or saved as Excel or PDF.
     Test parameters can be viewed and corrected.
     The test curve can be scaled and dragged.
     The original data, test results and test reports are provided