Place of Origin: | China |
Brand Name: | AI |
Certification: | ISO |
Model Number: | DRT |
Minimum Order Quantity: | 1 Set |
---|---|
Price: | Negotiable |
Packaging Details: | Plywood case |
Delivery Time: | 15 days |
Payment Terms: | T/T, Western Union, L/C |
Supply Ability: | 100 sets per month |
Power Supply: | AC220V10%45~65Hz | Power: | 55W |
---|---|---|---|
Pressure Measuring Range: | 0~1MPa | Temp.display Range: | -20℃~80℃ |
Display: | 320X240 LCD | Keyword: | SF6 Density Relay Calibration Test Kit |
Introduction
Power equipment which is insulated by SF gas should install Gas density relay to monitor the density change of the equipment. If the density of SF6 gas decreased to the threshold value the replay will operate to protect the equipment prevent insulation failure of the equipment. So the reliable operation of the relay is very important.
DRT SF6 gas density relay calibration test kit is applied to check and confirm whether the relay is operated in the correct value and feedback correct logical
sequence.
Feature
1) Measure the pressure in current temperature and calculate the pressure in 20 Celsius degree automatic. So the measured operation value of relay could be displayed in both the current temperature and 20 Celsius degree in the Portable SF6 Density Relay Calibration Test Kit
2) The test kit can be applied to test the SF6 Density relay in station. No laboratory condition is required for the operation value test because of the temperature transformation calculation.
3) Fast interface connector is very convenient and reliable.The standard configure of connector can meet most the requirement of most station application.
4) All the test procedure is controlled by the MCU during the whole test. All the measure value can be displayed in the large size LCD in one frame.
Technial specifications
S.N. | Item | Technical Specifications |
1 | Power supply | AC220V10%45~65Hz |
2 | Power | 55W |
3 | Measuring error | 0.2%RDG+2D |
4 | SF6 Density Relay | Single Alarm,single interlock,single alarming and interlock,single alarming and double interlok |
5 | Ambient gas pressure gauge | Calibrate any pressure point from 0 to 1MPa |
6 | 20° gas pressure gauge | Calibrate any pressure point from 0 to 1MPa |
7 | Pressure measuring range | 0~1MPa;Resolution:0.001MPa |
8 | Temperature display range | -20℃~80℃,Resolution:0.1C |
9 | Display mode | 320X240 LCD |
10 | Operation model | Rotating mouse |
11 | Printer | Thermal printer |
12 | Storage | it can save 96 pages result simultaneously |
13 | Display mode of SF6 density | Ambient pressure and Equivalent pressure at 20℃ |
14 | Working condition | -10℃~60℃ |
15 | Humidity | 90%RH |
Photo of Portable SF6 Density Relay Calibration Test Kit