Place of Origin: | China |
Brand Name: | AI |
Certification: | ISO |
Model Number: | 3100 |
Minimum Order Quantity: | 1 set |
---|---|
Price: | Negotiable |
Packaging Details: | Hardboard |
Delivery Time: | 20 days |
Payment Terms: | L/C, T/T, Western Union |
Supply Ability: | 20 sets per month |
Wavelength Range: | 190~700nm | Bandwidth: | 8nm |
---|---|---|---|
Path Length: | 10MM | Light Source: | Deuterium Lamp |
Keyward: | HPLC | Warranty: | 1 Year |
P3100 High Pressure Constant Flow Pump
◆ Flow rate range: 0.001-10.000 mL/min, in 0.001 mL increments
◆ Flow accuracy: ≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa)
◆ Flow precision: RSD≤0.06% (1.00ml/min, H2O,R.T.,8.5MPa)
◆ Maximum pressure: 45MPa
UV3100 UV/VIS Detector
Wavelength range | 190-700 nm |
Wavelength repeatability | ≤0.1 nm |
Wavelength accuracy | ≤±1.0 nm |
Bandwidth | 8nm |
Response time | 0.0 s-5 s |
Baseline noise | ≤±0.5×10-5 AU |
Drift | ≤1.0×10-4 AU/h (empty cell, 254 nm, 60 min) |
Path length | 10 mm(analytical cell) |
Light sourcw | Deuterium Lamp |
Chromsoft Chromatographic Data-processing Workstation
◆ Internal and external standard calculation methods
◆ Automatically displays, prints, exports and starts other programs after the completion of a measurement.
◆ Comply with the requirements of the 21 CFR Part 11 directive of the FDA
Eclassical 3100 System Kits
◆ Containing required tubing, fittings, wreches and cables for system.
◆ C18 column 5μm ID4.6×200mm
◆ 7725i manual injector
◆ TD-1-15 mixer
◆ User manual
RI-201H Refractive Index Detector
◆ Flow cell type:2 chamber-type
◆ Measuring method:Deflection type
◆ Refractive Index range:1.00 to 1.75
◆ Measuring range:0.25 to 512μRIU
◆ Drift:0.2μRIU/h (Pure water 1mL/min, PURGE OFF)
◆ Linearity range:≥600μRIU
◆ Noise:≤2.5nRIU (Pure water, response : 1.5sec)
◆ Response:0.1 , 0.25 , 0.5 , 1 , 1.5 , 2 , 3 , 6 sec
◆Cell volume:8μL
◆Flow rate:(Usual) 0.2 to 3.0mL/min;(Max.) 10mL/min (solvent: pure water)