Place of Origin: | CHINA |
Brand Name: | AI |
Certification: | ISO |
Model Number: | FRP-T |
Minimum Order Quantity: | 1 SET |
---|---|
Price: | Negotiable |
Packaging Details: | Plywood case |
Delivery Time: | 60 days |
Payment Terms: | Western Union, T/T, L/C |
Test Standard: | EN ISO 9239-1, ASTM E648, ASTM E970, NFPA 253 | Power Supply: | AC220V±10%, 50Hz;5KW |
---|---|---|---|
Ambient Temperature: | Operating 10°C To 35°C | Test Part: | Length1.4× Width1.0× High2.2 M³ |
Control Box: | 600(W)×750(D)×1600(H)mm | Weight: | 350kg |
Color: | Grey | Warrant: | 1 Year |
ISO 9239-1: Flooring fire reaction test - Part 1: Combustion performance of flooring materials tested by radiant heat
ASTM E 648: Critical Radiant Flux of Floor standard test - covering system uses radiant heat energy
ASTM E 970: Using a Radiant Heat Energy Source, test insulation floorinsulationinsulation standard test for Critical Radiant Flux
using a radiant heat energy.
NFPA 253: Standard Test Method for using radiant heat energy, test plates overlay system Critical Radiant Flux
1, All structural components of flooring radiant panel apparatus are made of stainless steel, nice appearance, corrosion resistance;
2, The radiation source is a porous ceramic heat radiating plate 300mmX450mm, tilted 30 °;
3, Imported calorimeter from US Medtherm company, range 50KW /m;
4, Igniters diameter of 0.7mm from the bottom of the center line of each 60-degree position according to standard request.
5, The standard plate is made of thick 20 ± 1mm, density 850 ± 100kg / m³ without coating made of calcium silicate board; size 1050X250mm
6, Small stainless steel auxiliary ignition burner ignited sample.
7, Imported flow control meter from Japan, precise control of the flow of propane
8, This flooring radiant panel apparatus is equipped with air blower providing air, mixed gas through the venturi mixing test gas,
9, The specimen holder is made of stainless steel and an overall dimension of 1140mm x 320 mm.
1, The optical system comprising a light source color temperature is 2900 ± 100 K incandescent,lightreceiving silicon photodiode with an optical path test shutter, 0% and 100%, to facilitate the use of calibration;
2, Imported light battery module measuring light attenuation. The system automatically calculates and generates a light transmittance curve translucent; printable Scribble
3, One button automatic and five level calibration system by computer.
1, Heat radiation pyrometer accuracy of ± 0.5 ºC, away from the radiation board about 1.4m;
2, Radiation pyrometer sensitivity constant in the wavelength range 1um ~ 9um;
3, High-performa
1 | Electrical | AC220V±10%, 50Hz;5KW |
2 | Ambient Temperature | Operating 10°C to 35°C |
3 | Dimensions |
Control box: 600(W)×750(D)×1600(H)mm Test part:Length1.4× width1.0× High2.2 M³ |
4 | Gas Supplies | Propane and air compressor |
5 | Weight | 350KG |